UPD Mail Archive: UPD> Re: IPP> min/max custom size values

UPD> Re: IPP> min/max custom size values

From: Michael Sweet (mike@easysw.com)
Date: Thu Mar 29 2001 - 16:31:08 EST

  • Next message: Mark VanderWiele: "Re: UPD> Re: IPP> min/max custom size values"

    Norbert Schade wrote:
    > ...
    > This would indicate that these two values are valid for all input
    > trays, which normally is wrong. These are input tray specific
    > values. I know that they can be affected by some other setting as
    > well like a duplexer. These conditions are certainly out of scope
    > of the global media list.

    That is correct, but I think we can add a fourth "rule" for the
    spec, which will apply to *all* attributes (remember, there are
    plenty of printers that can't print on cardstock from particular
    trays, too, so it ain't just an issue for custom sizes... :)

    I think this will be appropriate for the "scope" section; it
    should mention that the media spec just defines the values, not
    what will be supported for a particular combination, and that
    the underlying protocols must handle this mess themselves (e.g.
    IPP uses the media collection stuff or validate-job to determine
    the valid combinations of values...)

    -- 
    ______________________________________________________________________
    Michael Sweet, Easy Software Products                  mike@easysw.com
    Printing Software for UNIX                       http://www.easysw.com
    



    This archive was generated by hypermail 2b29 : Thu Mar 29 2001 - 16:31:37 EST