PMP Mail Archive: FW: PMP> difficulty in loading rfc1759 MIB

FW: PMP> difficulty in loading rfc1759 MIB

Hastings, Tom N (hastings@cp10.es.xerox.com)
Wed, 17 Mar 1999 10:39:47 -0800

-----Original Message-----
From: OGrant [mailto:OGrant@PEC.com]
Sent: Wednesday, March 17, 1999 06:33
To: 'Hastings, Tom N'
Subject: RE: PMP> difficulty in loading rfc1759 mib

fyi, printer-mibv1.mib failed with the same message; printer-mib.mib
installed successfully, however - thanks for your assistance.

> -----Original Message-----
> From: Hastings, Tom N [SMTP:hastings@cp10.es.xerox.com]
> Sent: Wednesday, March 17, 1999 3:16 AM
> To: OGrant
> Cc: 'pmp@pwg.org'
> Subject: RE: PMP> difficulty in loading rfc1759 mib
>
> RFC 1759 does not compile after being stripped (using mstrip).
>
> You could try either of the .mib files which are RFC 1759 stripped and are
> located at:
>
> ftp://ftp.pwg.org/pub/pwg/pmp/mibs/Printer-MIBv1.mib
> ftp://ftp.pwg.org/pub/pwg/pmp/mibs/Printer-MIB.mib
>
> Or you could try the newer Internet-Draft that is intended to supersede
> RFC
> 1759 which is available at:
>
>
>
> -----Original Message-----
> From: lpyoung@lexmark.com [mailto:lpyoung@lexmark.com]
> Sent: Thursday, January 28, 1999 12:27
> To: pmp@pwg.org
> Subject: PMP> Latest Printer MIB internet draft
>
>
> When I did not hear of any changes in the latest Printer MIB
> document and in anticipation of publishing the Printer MIB as
> a Draft Standard, I sent the document on to the Internet Draft
> editor. The Internet Draft document is at:
>
> ftp://ftp.pwg.org/pub/pwg/pmp/drafts/draft-ietf-printmib-mib-info-04.txt
>
> The only changes in the document versus the last one I published
> is the date on the document and the I-D expiration date.
>
> Regards,
> Lloyd
>
> ------------------------------------------------------------
> Lloyd Young Lexmark International, Inc.
> Senior Program Manager Dept. C14L/Bldg. 035-3
> Strategic Alliances 740 New Circle Road NW
> internet: lpyoung@lexmark.com Lexington, KY 40550
> Phone: (606) 232-5150 Fax: (606) 232-6740
>
>
> -----Original Message-----
> From: OGrant [mailto:OGrant@PEC.com]
> Sent: Tuesday, March 16, 1999 14:22
> To: 'pmp@pwg.org'
> Subject: PMP> difficulty in loading rfc1759 mib
>
>
> I'm currently using Tivoli's Netview 5.1 for NT, and received the
> following
> message when attempting to load the above mib:
>
> Line 14: Error defining object: found 'MODULE-IDENTITY'
>
> Expected one of the following:
> OBJECT IDENTIFIER
> OBJECT-TYPE
> TRAP-TYPE
> ::=
>
> I confirmed that rfc's 1213 and 1514 were both loaded prior to loading the
> above; however, the install still failed - any suggestions?
> Thanks much,
>
> Oliver M. Grant
> Performance Engineering Corp.