"When a non-critical condition occurs, the printer may choose to stop
printing by going offline (e.g., when a toner low condition occurs, the
printer might stop to notify the user); in which case there would be two
alerts entered into the alert table, one for the error condition and one
for the offline condition. The offline condition is considered to be the
critical alert that is stopping printing. Putting the printer online
without fixing the error condition causes the offline alert to be removed
from the table, but the non-critical alert remains in the table until the
error condition is fixed."
Bob
----------
From: Chuck Adams[SMTP:adamsc@pogo.WV.TEK.COM]
Sent: Thursday, May 01, 1997 9:33 AM
To: pmp@pwg.org
Subject: PMP> Top 25 minus 4 conditions/alerts proposal
Folks,
I have posted the proposed Appendix wording for the
the Top 25 minus 4 alerts document to the ftp site. See:
ftp://pwg.org/pub/pwg/pmp/contributions/err4.doc
ftp://pwg.org/pub/pwg/pmp/contributions/err4.pdf
I believe this reflects all the changes requested
in the Wednesday conference call.
Chuck Adams
Tektronix, Inc.