Angelo, Looking at the definitions of prtInputManualFeedTimeout (which is supposed
to be prtInputMediaLoadTimeout), prtInputAutoSwitch and your new definition
of prtInputNextIndex, it looks like we've got too many controls for what we
need to do.

The objective is to have a timeout when the needed media is not available.
The timeout requirement is satisfied by prtInputMediaLoadTimeout. The
action to be taken can be controlled by prtInputNextIndex, as you've
defined it if you change the wording to "A value of zero(0) indicates that
auto input switching will not occur and the job will be aborted when this
input subunit is emptied." I don't see the need for prtInputAutoSwitch to
control switching, when prtInputNextIndex can determine the action to be
taken.

You claim that prtInputNextIndex is not necessary, but you don't explain
why. I see that it is needed for the printers that wish to allow the next
input subunit to be configurable. For HP printers, we would support only
values of zero and -2 since we don't know which tray we will switch to
until the load media request is generated.

When we discussed this at the meeting on Friday afternoon, I didn't realize
that there were multiple controls. This looks like a case where we can do
some simplification, but let's not delete the wrong object.

Let me know if I'm missing something.

Bob Pentecost
HP

prtInputManualFeedTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
MIN-ACCESS read-only
STATUS current
DESCRIPTION
"The duration (in seconds) after which the printer shall
either:

(a) switch to another input subunit, if the value of
prtInputNextIndex is non-zero and prtInputAutoSwitch
is on(3)
or
(b) abort any job waiting for manually fed input, if the
value of prtInputNextIndex is zero or
prtInputAutoSwitch is off(4) or notPresent(5).

The event which causes the printer to enter the waiting state
is product specific. A value of (-1) implies 'other' or
'infinite' which translates to 'this input subunit doesn't
support manual feed'. A value of (-2) implies 'unknown'."
::= { prtInputEntry 24 }

prtInputAutoSwitch OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
MIN-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the state of the auto input switching feature. The
value notPresent(5) indicates the feature is not currently
supported. Exact behavior of this feature is product specific."
::= { prtInputEntry 25 }

----------
From: Caruso,Angelo[SMTP:Angelo_Caruso@wb.xerox.com]
Sent: Monday, January 13, 1997 5:19 PM
To: pmp@pwg.org
Subject: PMP> The Input Switching Group

One of my action items from the Albuquerque meeting is to refine and
justify the new objects in the Input Switching Group. Here is my first
crack at refining these objects:

prtInputNextIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
MIN-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prtInputIndex corresponding to the input subunit
which will be used when this input subunit is emptied. A value
of zero(0) indicates that auto input switching will not occur
when this input subunit is emptied. A value of (-1) means other.
The value (-2) means 'unknown' and specifically indicates that
an implementation specific method will determine the next input
subunit to use at the time this subunit is emptied. The value
(-3) means input switching is not supported for this subunit."

Based on the new description above, I am once again of the opinion that
the prtInputAutoSwicth object is uneccessary. Did I forget anything
from the discussion Friday afternoon? Any other comments?