Hi Jay,
You are right, the value should be 1.3.6.1.2.1.25.3.1.5.
The other value (1.3.6.1.2.1.25.3.2.1.2.1) is actually the OID for the
hrDeviceType instance itself - ie they are setting the value of the
object equal to the object's OID name.
Steve
On Fri, 30 Aug 1996, JK Martin wrote:
> Hi Steve,
>> I'm having a bit of trouble developing the algorithm to resolve
> the first printer registered in a HR MIB device table, and I
> was hoping you could help me out.
>> My understanding of hrDeviceType is that it should contain an OID
> describing the type of device, and that for a printer, this value
> should be: 1.3.6.1.2.1.25.3.1.5
>> Is this correct?
>> My recent testing indicates that at least two printer vendors are
> setting the OID value as: 1.3.6.1.2.1.25.3.2.1.2.1
>> Since both vendors report the same value, I'm thinking that perhaps
> I am misunderstanding the situation.
>> Any help would be greatly appreciated!
>> ...jay
>> ----------------------------------------------------------------------
> -- JK Martin | Email: jkm at underscore.com --
> -- Underscore, Inc. | Voice: (603) 889-7000 --
> -- 41C Sagamore Park Road | Fax: (603) 889-2699 --
> -- Hudson, NH 03015-4915 | Web: http://www.underscore.com --
> ----------------------------------------------------------------------
>