PMP> RE: Adding ppmPortDescription to Port Mon MIB

PMP> RE: Adding ppmPortDescription to Port Mon MIB

Bergman, Ron Ron.Bergman at rpsa.ricoh.com
Mon Apr 25 13:08:15 EDT 2005


Ira,
 
One of the goals of this MIB was to keep it light weight and not load it up with all the normal extras we
put in the MIB to meet all the imposed requirements.  In this case it does not seem to be necessary to
have both a descriptive name and a description.  Both Mike and Paul have agreed.  If we follow your
suggestion, the name will end up being a very generic name installed by the manufacturer and not of
much use to the "port installer" function.  The whole purpose of calling this a descriptive name was to
eliminate the need for the 2 objects.  Let's change the object name to reflect this change to 
"ppmPortDescrName" so it doesn't violate are "rules".
 
Also, the need to restore "ppmPortChannelIndex" based upon its ability "to disambiguate (for example)
Text vs Binary LPR channels" is incorrect.  The Channel Table does not provide any information regarding
Text vs Binary.
 
    Ron

-----Original Message-----
From: McDonald, Ira [mailto:imcdonald at sharplabs.com]
Sent: Saturday, April 23, 2005 2:32 PM
To: Bergman, Ron; Mike Fenelon; McDonald, Ira; Paul Danbold
Cc: pmp at pwg.org; Harry Lewis (E-mail); Ivan Pavicevic
Subject: RE: Adding ppmPortDescription to Port Mon MIB


Hi,
 
Forgive the delay in response - I was offline packing for two days.
 
There's a PWG Semantic Model naming convention for elements here
that's important (and agrees with Mike's intended usage).
 
In the Semantic Model (and in IPP) there are two distinct base datatypes:
Name (restricted character set, leaving out most non-alpha/non-digit) and
Text (unrestricted character set, except that most control characters are
still invalid).
 
In Printer MIB, Job MIB, SM/1.0, and IPP there are numerous elements
that are called 'XxxName' (e.g., prtInputName in the Printer MIB) that are
_static_ and SHOULD NOT be changed (or lost across reboots) after
device installation (when the Administrator can override the Factory default 
name).  Such elements are used in SM/1.0 as _keys_ (for object lookup).
 
In Printer MIB, etcm there are also numerous elements that are called
'XxxDescription' (e.g., prtInputDescription) that are _dynamic_ and SHOULD
be changed when the current configuration of the element is modified
by an Operator or Administrator.  Such elements are never used as keys.
 
An element called (or used) ppmPortNameOrDescription _cannot_ be added
to the Semantic Model (because it breaks existing strong typing in our XML 
schema).
 
The Apple request can only be satisfied by a separate, dynamic text object.
 
Cheers,
- Ira
 
 

Ira McDonald (Musician / Software Architect)
Blue Roof Music / High North Inc
PO Box 221  Grand Marais, MI  49839
phone: +1-906-494-2434
email: imcdonald at sharplabs.com 

-----Original Message-----
From: Bergman, Ron [mailto:Ron.Bergman at rpsa.ricoh.com]
Sent: Thursday, April 21, 2005 3:24 PM
To: Mike Fenelon; McDonald, Ira; Paul Danbold
Cc: pmp at pwg.org; Harry Lewis (E-mail); Ivan Pavicevic
Subject: RE: Adding ppmPortDescription to Port Mon MIB


Mike,
 
The ppmPortName object may contain a maximum of 127 characters.
Does this meet your requirement?
 
   Ron
 

-----Original Message-----
From: Mike Fenelon [mailto:mfenelon at windows.microsoft.com]
Sent: Thursday, April 21, 2005 9:59 AM
To: Bergman, Ron; McDonald, Ira; Paul Danbold
Cc: pmp at pwg.org; Harry Lewis (E-mail); Ivan Pavicevic
Subject: RE: Adding ppmPortDescription to Port Mon MIB



The intent of this object is to give a short, concise user-friendly name of the port. It will be presented in the User Interface for and device that advertises more than one port so the user can pick the correct port for their connected printer. The whole intent was to differentiate between multiple ports on a  device that could host multiple printers. I am concerned we will start  degrading the user experience if we add a whole bunch of ports for the same printer with slightly different names.

 

Mike Fenelon
Microsoft

 


  _____  


From: Bergman, Ron [mailto:Ron.Bergman at rpsa.ricoh.com] 
Sent: Thursday, April 21, 2005 9:32 AM
To: McDonald, Ira; Paul Danbold
Cc: pmp at pwg.org; Harry Lewis (E-mail); Mike Fenelon; Ivan Pavicevic
Subject: RE: Adding ppmPortDescription to Port Mon MIB

 

Ira,

 

I would like to hear from Mike or Ivan on this subject, rather than rely on memory.

Your comment does not agree with the current description clause for this object.

 

    Ron

-----Original Message-----
From: McDonald, Ira [mailto:imcdonald at sharplabs.com]
Sent: Thursday, April 21, 2005 8:37 AM
To: 'Paul Danbold'; Bergman, Ron
Cc: pmp at pwg.org; Harry Lewis (E-mail); McDonald, Ira; MFenelon at microsoft.com; IvanP at microsoft.com
Subject: RE: Adding ppmPortDescription to Port Mon MIB

Hi Ron,

 

Doesn't work - MS specifically said that they wanted PortName restricted

to a _name_ that they will display in their tools and do NOT want it to

include descriptive text.  Your memory is incorrect.

 

Cheers,

- Ira

 

Ira McDonald (Musician / Software Architect)
Blue Roof Music / High North Inc
PO Box 221  Grand Marais, MI  49839
phone: +1-906-494-2434
email: imcdonald at sharplabs.com 

-----Original Message-----
From: Paul Danbold [mailto:danbold at apple.com]
Sent: Wednesday, April 20, 2005 11:55 PM
To: Bergman, Ron
Cc: pmp at pwg.org; Harry Lewis (E-mail); Ira McDonald (E-mail 3); MFenelon at microsoft.com; IvanP at microsoft.com
Subject: Re: Adding ppmPortDescription to Port Mon MIB

Ron, 

 

Thanks for the clarification.  In the expectation that manufacturers will initialize ppmPortName with helpful information, I am satisfied there is no need to add an additional object.

 

-Paul

 

---------------------------------------------------------------

Paul Danbold

Imaging Technologies Evangelist, Apple Worldwide Developer Relations

3 Infinite Loop, MS:303-2TE, Cupertino, CA 95014

408-974-0050 (office)  408-425-3351 (mobile)

---------------------------------------------------------------

 

 

On Apr 15, 2005, at 9:48 AM, Bergman, Ron wrote:





I remembered this morning why we decided, several months back, to remove this object. 
Since the MIB contained both a desciptive name and a description, it was agreed that 
the two objects were redundant.  To clarify this situation I recommend that the object 
ppmPortName be changed to ppmPortDescriptiveName or ppmPortDescription, rather 
than go back to the original redundant pair. 

ppPortName is a natural language string with up to 127 characters.  For Paul Danbold's 
example I could provide a name such as: 

        "Networked LPR port providing binary PostScript printing for use by marketing" 

This is less than 80 characters and should be more than sufficient to satisfy Paul's 
requirement. 

Also, in addition to a possible name change, it must be noted that this object is 
expected to be administratively configured using an out-of-band method. 

Paul, please indicate if this is sufficient. 

        Ron Bergman 
        Ricoh Printing Systems America 

 

 

 

-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://www.pwg.org/archives/pmp/attachments/20050425/25b99b9a/attachment-0001.html


More information about the Pmp mailing list