Hi folks,                                          Monday (25 July 2005)

Below are proposed updates for missing 'out-of-band' values to three
textual conventions defined in the IANA-PRINTER-MIB.  These missing
'unknown(2)' values were technical errors in Printer MIB v1 (RFC 1759)
and Printer MIB v2 (RFC 3805).

These updates will allow the new Printer Port Monitor MIB to use a
syntax of PrtChannelTypeTC for the ppmPortProtocolType object (as
recently requested by Bert Wijnen).  These updates should also improve
interoperability among Printer MIB implementations (they are all the
appropriate default values).

After review, these additions should be sent to IANA for registration
in the IANA-PRINTER-MIB by our Designated Experts, Bert Wijnen and Harry
Lewis.

Comments?

Cheers,
- Ira (co-editor of Printer MIB v2)


Ira McDonald (Musician / Software Architect)
Blue Roof Music / High North Inc
PO Box 221  Grand Marais, MI  49839
phone: +1-906-494-2434
email: imcdonald at sharplabs.com

------------------------------------------------------------------------

(1) PrtCoverStatusTC - add
        unknown(2),          -- Not in RFC 1759

(2) PrtChannelTypeTC - add
        unknown(2),          -- Not in RFC 1759

(3) PrtAlertGroupTC - delete

(4) PrtAlertGroupTC - add
        unknown(2),          -- Not in RFC 1759
        -- (2) is reserved for conformance information