FW: PMP> Add 'percent(19)' to 'PrtCapacityUnitTC' and 'PrtMarkerS uppliesUn itTC'

FW: PMP> Add 'percent(19)' to 'PrtCapacityUnitTC' and 'PrtMarkerS uppliesUn itTC'

Bergman, Ron Ron.Bergman at Hitachi-hkis.com
Tue Nov 21 11:40:44 EST 2000


All,

Ira McDonald has proposed the addition of 'percent(19)' 
to the textual conventions 'PrtCapacityUnitTC' and
'PrtMarkerSuppliesUnitTC'.

I believe that this can be accomplished during the 
RFC Editors cycle.

If anyone has any objections to this new enumeration
please state your reasons before December 18, 2000.

	Ron Bergman
	Hitachi Koki Imaging Solutions


-----Original Message-----
From: McDonald, Ira [mailto:imcdonald at sharplabs.com] 
Sent: Friday, November 17, 2000 11:26 AM
To: 'pmp at pwg.org'; 'fin at pwg.org'
Subject: PMP> Add 'percent(19)' to 'PrtCapacityUnitTC' and
'PrtMarkerSuppliesUn itTC'


Hi,

Implementors here at Sharp have found a serious problem with
'prtInputCurrentLevel', 'prtOutputRemainingCapacity' and
'prtMarkerSuppliesLevel'.

Their related units objects need 'percent(19)' added to
allow reporting of RELATIVE levels (often the only
information known from sensors).

- 'PrtCapacityUnitTC' should have 'items(18)' (per Ron B 
  and Harry L) and 'percent(19)' added 
- 'PrtMarkerSuppliesSupplyUnitTC' should have 'percent(19)' 
  added

BOTH of these textual conventions should also have 'other(1)'
and 'unknown(2)' added - this would provide short-term
relief to the NEXT product team that finds a missing unit
AFTER the Printer MIB v2 is published as an RFC.

Cheers,
- Ira McDonald, consulting architect at Sharp
  High North Inc



More information about the Pmp mailing list