PMP> FIN> Add 'percent(19)' to 'PrtCapacityUnitTC' and 'PrtMarkerSuppliesUn itTC'

PMP> FIN> Add 'percent(19)' to 'PrtCapacityUnitTC' and 'PrtMarkerSuppliesUn itTC'

Dennis Carney dcarney at us.ibm.com
Fri Nov 17 14:57:24 EST 2000


Ira,

What are you going to return for prtInputMaxCapacity when
prtInputCapacityUnit is 'percent'? 100?  The same capacity unit is used for
both max capacity and current level, and 'percent' fits one but not the
other.

Dennis Carney
IBM Printing Systems
---------------------- Forwarded by Dennis Carney/Boulder/IBM on 11/17/2000
12:56 PM ---------------------------

"McDonald, Ira" <imcdonald at sharplabs.com>@pwg.org on 11/17/2000 12:25:50 PM

Sent by:  fin-owner at pwg.org


To:   "'pmp at pwg.org'" <pmp at pwg.org>, "'fin at pwg.org'" <fin at pwg.org>
cc:
Subject:  FIN> Add 'percent(19)' to 'PrtCapacityUnitTC' and
      'PrtMarkerSuppliesUn itTC'



Hi,

Implementors here at Sharp have found a serious problem with
'prtInputCurrentLevel', 'prtOutputRemainingCapacity' and
'prtMarkerSuppliesLevel'.

Their related units objects need 'percent(19)' added to
allow reporting of RELATIVE levels (often the only
information known from sensors).

- 'PrtCapacityUnitTC' should have 'items(18)' (per Ron B
  and Harry L) and 'percent(19)' added
- 'PrtMarkerSuppliesSupplyUnitTC' should have 'percent(19)'
  added

BOTH of these textual conventions should also have 'other(1)'
and 'unknown(2)' added - this would provide short-term
relief to the NEXT product team that finds a missing unit
AFTER the Printer MIB v2 is published as an RFC.

Cheers,
- Ira McDonald, consulting architect at Sharp
  High North Inc






More information about the Pmp mailing list