PMP> Re: Requested change to HR MIB

PMP> Re: Requested change to HR MIB

Ron Bergman rbergma at dpc.com
Mon Aug 23 20:04:15 EDT 1999


I also vote to remove this column completely.  Since in many cases today
this information is not correct, it just adds to the confusion.  When
"Typically Appropriate" is not typical and looks like a specification it
is best to leave it blank.

	Ron Bergman
	Hitachi Koki Imaging Solutions
 

On Mon, 23 Aug 1999 harryl at us.ibm.com wrote:

> 
> 
> Implementations had found a few cases where the fixed association between
> hrPrinterDetectedErrorState bits and hrDeviceStatus were inappropriate. The
> initial recommendation was to add warning or down for each bit. Later, we
> requested to just REMOVE the hrDeviceStatus column altogether since
> SPECIFICATION of an association was not feasible in all circumstances.
> 
> If the new wording is clear that these are LIKELY associations but not mandated,
> I guess that's ok too, but I'd rather see this as an example. I believe the
> current draft appears too much like a specification (that MUST be followed).
> 
> Harry Lewis
> IBM Printing Systems
> harryl at us.ibm.com
> 
> 
> Steve Waldbusser <waldbusser at ins.com> on 08/23/99 01:53:03 PM
> 
> To:   hostmib at andrew.cmu.edu
> cc:
> Subject:  PMP> Re: Requested change to HR MIB
> 
> 
> 
> 
> 
> 
> This problem was solved a different way.
> 
> The new text (ini the current draft) clarifies that "The hrDeviceStatus column
> shows the hrDeviceStatus which is typically appropriate when such an error
> condition exists." In other words, there isn't a strict algorithmic
> translation between errorState bits and deviceStatus. deviceStatus should be
> set based on the operational status of the printer. errorState bits should be
> set based on any detected errors. If the noPaper condition is set but the
> printer is still able to run, this would be highly unusual, but OK. The
> deviceStatus column just suggests the most likely condition.
> 
> Adding warning or down to all rows is less useful and actually provides less
> flexibility than implementors might need.
> 
> Steve
> 
> 
> > From: lpyoung at lexmark.com
> >
> > Please change the description of hrPrinterDetectedErrorState:
> >
> > Original Text
> >              Condition         Bit #    hrDeviceStatus
> >
> >              lowPaper              0        warning(3)
> >              noPaper               1        down(5)
> >              lowToner              2        warning(3)
> >              noToner               3        down(5)
> >              doorOpen              4        down(5)
> >              jammed                5        down(5)
> >              offline               6        down(5)
> >              serviceRequested      7        warning(3)
> >              inputTrayMissing      8        warning(3)
> >              outputTrayMissing     9        warning(3)
> >              markerSupplyMissing  10        warning(3)
> >              outputNearFull       11        warning(3)
> >              outputFull           12        warning(3)
> >              inputTrayEmpty       13        warning(3)
> >              overduePreventMaint  14        warning(3)
> >
> > Revised Text
> >              Condition           Bit #    hrDeviceStatus
> >
> >              lowPaper            0        warning(3) or down(5)
> >              noPaper             1        warning(3) or down(5)
> >              lowToner            2        warning(3) or down(5)
> >              noToner             3        warning(3) or down(5)
> >              doorOpen            4        warning(3) or down(5)
> >              jammed              5        warning(3) or down(5)
> >              offline             6        warning(3) or down(5)
> >              serviceRequested    7        warning(3) or down(5)
> >
> >              inputTrayMissing    8        warning(3) or down(5)
> >              outputTrayMissing   9        warning(3) or down(5)
> >              markerSupplyMissing 10       warning(3) or down(5)
> >              outputNearFull      11       warning(3) or down(5)
> >              outputFull          12       warning(3) or down(5)
> >              inputTrayEmpty      13       warning(3) or down(5)
> >              overduePreventMaint 14       warning(3) or down(5)
> >
> > Reason for change:
> > The original text would seem to require all printers to respond
> > identically in hrDeviceStatus on the same error condition. Reality
> > is that different printers respond differently on the same error
> > condition. What might be a warning in one printer may be a down
> > condition in another printer. Even within a printer a single error
> > condition might be a warning one time and a down condition another
> > time. For example, several printers support the linking of multiple
> > paper trays together to form one logical paper tray, when one of the
> > linked trays runs out of paper the printer will start feeding paper
> > from one of the other linked trays, the printer may report noPaper
> > but it is a warning condition because paper is being fed from
> > another tray.
> >
> > Lloyd
> > ------------------------------------------------------------
> > Lloyd Young
> > Manager, Alliances and Complementary Project Development
> > Consumer Printer Division         Lexmark International, Inc.
> > Dept. C88M/Bldg. 005-1            740 New Circle Road NW
> > email: lpyoung at lexmark.com        Lexington, KY 40550-0001
> > Phone: (606) 232-5150             Fax: (630) 982-4032
> >
> > ----------------
> 
> 
> 
> 
> 




More information about the Pmp mailing list