The following are editorial issues that I found in the latest Printer MIB 
document.


1. PrtCoverStatusTC needs to include the following statement: "--  This 
value is a type 2 enumeration"
2. PrtInputTypeTC needs to include the following statement: "--  This value 
is a type 2 enumeration"
3. PrtSubUnitStatusTC needs to include the following statement: "--  This 
value is a type 1 enumeration"
4. The prtAlertSeverityLevel line of PrtAlertEntry is incorrect. Change 
"PrtSeverityLevelTC," to "PrtAlertServerityLevelTC,".


Jeff Rackowitz
Intermec Corp.
jeffr at intermec.com