PMP> Revised Test Plan

PMP> Revised Test Plan

Chris Wellens chrisw at iwl.com
Fri Jan 17 14:28:14 EST 1997


Gail,


I look forward to seeing your revised test plan.


On Fri, 17 Jan 1997, Gail Songer wrote:


> On Jan 16, 11:56pm, Chris Wellens wrote:
> > Subject: PMP> Revised Test Plan
> 
> >For all the items listed in #6 below, InterWorking
> >Labs has tests.  We are modifying the output of the
> >tests so that only the data containing the name of the
> >object and its current value is included in an output
> >file. That way we get only the test results reflecting
> >a list of all objects and their values for each printer.
> Exactly what do the tests do? How does it differ from the mib walk?
> 
> > 4.  Do a MIB walk on each product and count the returned objects.
> I assume that you are saving the responces?
> 
> > 5.  Generate controlled (in a pre-defined script) printer specific
> > transactions, including jobs in various formats and various sizes
> > (known page counts), postscript files, raw ascii, and specific applications
> > (e.g. Word, Navigator, Quicken).
> What is the purpose of printing lots of jobs?  The only thing I can think of is
> to make sure that the page count increments appropriately, and that can be done
> with one or two jobs.
> 
> > 6.  Start the test software application for the following areas.  After
> > completing the test for each line item, check to make sure the values of
> > the individual objects are contained in the specified output file.
> >
> 
> >
> > Trap Test:  coverOpen
> > Trap Test: noPaper
> > Trap Test: noToner
> > Trap Test: paperjam
> Is the trap table going to be read?  What about the sub-unit status and the 3
> magic host resourses objects?
> 
> >
> > 6.  Compare the values of the objects in each area returned from each
> > printer.  Make a list of all variations.  Decide on how the spec should
> > be modified.
> Deciding on the spec should be modified will be done at some later date, right?
> 
> >-- End of excerpt from Chris Wellens
> 
> It is my opinion that you will find lots of differences in very key areas.
>  Most developers can figure out the size of media path and what is on the front
> panel. The problem is that the sub unit status variables and the 3 magic host
> resources variables are ill-defined and as such there has been lots of
> interpretation.
> 
> For example, the definition of off-line varies between manufacturers.  What
> should prtInputStatus say when there is load paper for the tray?  What should
> it say when there is no paper in the tray but there is not a load paper
> condition for this tray?  What should hrPrinterDetectedErrorState say(this
> object defines noPaper as "down" for hrDeviceStatus, but the printer is
> definately not in that state)?
> 
> There needs to be some focus on these types of conditions since this is where
> the spec is the weakest.
> 
> Gail
> 
> 
> -- 
> 
> Gail Songer                                             Electronics For Imaging
> gail.songer at eng.efi.com                                 2855 Campus Drive
> (415) 268-7235                                          San Mateo, CA 94403
> 
> 



More information about the Pmp mailing list