Pete,
Thanks for posting this. I did a quick page turning and came up with the following comments:
- Global: Use the "normal" style for tables and their footnotes
- Global: Check for empty rows in tables and extra blank lines in the text.
- Table 7: The 8-bit RGB color keyword should probably be rgb_8 instead of color_8, to be consistent with the rest of them.
- Section 8.2.1.1, line 698 in the rev version: attribute names should be in double quotes, fix "job-password-encryption" (missing hyphen)
- Section 8.4.2.5: Same as 8.2.1.1
- Section 8.4.2.6: "destination-attributes" should be hyphenated and in double quotes, plus same fixes as 8.2.1.1.
- Section 10: I'd drop the "for more information see [BONJOUR]" and instead include the reference at the end of the first sentence with the new RFCs (6762 and 6763 IIRC - they are listed on the IPP WG web page).
- Table 9: Default value for rs should be "ipp/scan". "UUID" is all caps and MUST match the "printer-uuid" for the Print service, if any (remember, this is shared with the Print registration)
- Section 10: You should say something about the service name and TXT record being shared on a multifunction device.
- Section 10.3.1.1: You should say something about the TXT record being shared with the Print service on a multifunction device.
- Section 10.3.1.2: You don't have to include txtvers (it defaults to 1), but if you do it should be the first key.
- Section 10.3.1.3: The ending dot indicates a FQDN. The default port is 80 for http and 443 for https. I don't know if we should say anything about UI here.
- Section 10.3.1.4: IPP-SE? No mention of ipp/scan default value, sp and rp are both shown as keys in the examples.
- Section 10.3.1.7: ALL CAPS UUID, it is an RFC 4122 conforming UUID without the leading urn:uuid:, must match the "printer-uuid" value from the Print service, etc.
- Section 10.3.1.x: Examples should be for non-default values.
- Section 11: "002E" at end of sentence.
- Section 11.1: Item 2 drop the a-d sub-items
- Section 11.2: Item 2 drop the a-b sub-items
- Section 12: Fix list
- Section 13: "In addition to the security considerations defined below, the IPP extensions ..."
- Section 13.x: I don't think we have defined terms for all of the terms in these sections.
- Section 14.1: Drop "IPP" from in front of Printer Description, drop input-color-mode-default/-supported
- Section 14.2: Drop "bi-level" (already registered), "color_8" should be "rgb_8".
- Section 14.3: The enum is for operations-supported
- Section 15.1: Add RFC 6762, 6763, fix JFIF reference (pointing to RFC 6068)
- Section 15.2: Update IPPS reference
On May 9, 2014, at 7:28 AM, Zehler, Peter <Peter.Zehler at xerox.com> wrote:
> All,
> I have posted the stable version of “IPP Scan Service updated per prototype experience and subsequent discussions.
>>ftp://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509.pdf>http://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509.pdf>>ftp://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509.docx>http://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509.docx>>ftp://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509-rev.pdf>http://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509-rev.pdf>>ftp://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509-rev.docx>http://ftp.pwg.org/pub/pwg/ipp/wd/wd-ippscan10-20140509-rev.docx>>>> Peter Zehler
>> Xerox Research Center Webster
> Email: Peter.Zehler at Xerox.com> Voice: (585) 265-8755
> FAX: (585) 265-7441
> US Mail: Peter Zehler
> Xerox Corp.
> 800 Phillips Rd.
> M/S 128-25E
> Webster NY, 14580-9701
>>> _______________________________________________
> ipp mailing list
>ipp at pwg.org>https://www.pwg.org/mailman/listinfo/ipp
_________________________________________________________
Michael Sweet, Senior Printing System Engineer, PWG Chair
Our website uses cookies on your device to give you the best user experience. By using our website, you agree to the placement of these cookies. To learn more, read our privacy policy. Read Privacy Policy