IPP> NOT - Agreements on the ISSUES in the IPPGET spec and IPP base spec

IPP> NOT - Agreements on the ISSUES in the IPPGET spec and IPP base spec

Michael Sweet mike at easysw.com
Thu Jul 19 21:55:20 EDT 2001


"Hastings, Tom N" wrote:
> ...
> TH> Anyone have any thoughts?
> 
> TH> One possibility would be to add a "notify-status-code"
> attribute that can be returned in an Event Notification Attributes
> group along with Event Notification attributes.  The value would
> indicate that this is the last group for now.  We've done a similar
> status code in a Group thing for INDP Send-Notifications Attribute
> Groups.

After thinking on this a while, I think we need something like this
or another special value tag ("end-of-group" tag?) so that the client
knows that it can go off and process the event data and check back
later for more info (with the same connection...)

-- 
______________________________________________________________________
Michael Sweet, Easy Software Products                  mike at easysw.com
Printing Software for UNIX                       http://www.easysw.com