IPP> MOD - comments on Carl's Set and Admin operations regist ration [some questions]

IPP> MOD - comments on Carl's Set and Admin operations regist ration [some questions]

Hastings, Tom N hastings at cp10.es.xerox.com
Mon Jun 28 20:12:33 EDT 1999


Carl,

A couple of questions on your proposed operation attributes:

-----Original Message-----
From: kugler at us.ibm.com [mailto:kugler at us.ibm.com]
Sent: Wednesday, June 23, 1999 09:23
To: ipp at pwg.org
Cc: hastings at cp10.es.xerox.com; alimpich at us.ibm.com; longstaf at us.ibm.com
Subject: Re: IPP> MOD - comments on Carl's Set and Admin operations
registration pr

snip...

2) Rename "Backspace-Current-Job" to "Space-Current-Job"  and add these
OPTIONAL
 request operation attributes:

snip...

"non-process-run-out" (boolean) specifies whether the printer should perform
an
NPRO (move the last printed sheet to the stacker) before restarting
printing.
An NPRO makes it easier to see exactly where the spacing took place.

TH1> What is the behavior if the client omits this attribute?  The 'true' or
the 'false' behavior?  (I hope it isn't implementation-dependent).

TH2> What is the behavior if the implementation does not support this
operation attribute?  The 'true' or the 'false' behavior?  (I hope it isn't
implementation-dependent).

snip...

3)  Add the following OPTIONAL operation attributes to the Shutdown-Printer
request:
"non-process-run-out" (boolean) specifies whether the printer should perform
an
NPRO (move the last printed sheet to the stacker) before shutting down.

TH3> What is the behavior if the client omits this attribute?  The 'true' or
the 'false' behavior?  (I hope it isn't implementation-dependent).

TH4> What is the behavior if the implementation does not support this
operation attribute?  The 'true' or the 'false' behavior?  (I hope it isn't
implementation-dependent).

"synchronize" (boolean) specifies whether to synchronize the checkpoint data
for
the current job with the pages that have actually printed.  If this
attribute is
supported, a value of true implies that the Printer will be able to resume
the
job at the point of synchronization when restarted.

TH5> What is the behavior if the client omits this attribute?  The 'true' or
the 'false' behavior?  (I hope it isn't implementation-dependent).

TH6> What is the behavior if the implementation does not support this
operation attribute?  The 'true' or the 'false' behavior?  (I hope it isn't
implementation-dependent).

snip...

    -Carl




More information about the Ipp mailing list