IPP> MOD - Model document questions

IPP> MOD - Model document questions

Carl Kugler kugler at us.ibm.com
Thu Sep 17 11:45:59 EDT 1998


All,
> 
> I am forwarding the following message from Henrik. It was previously sent 
> only to the bake-off participants, while the IPP DL was down.
> 
> Carl-Uno 
> 
> -----Original Message-----
> From: henrik.holst at i-data.com [mailto:henrik.holst at i-data.com] 
> Sent: Friday, September 11, 1998 2:53 AM
> Subject: Model document questions
> 
> 
> I've got following questions when I read and implement the model document.
> 
> 1. In section 4.1.11 the the words say that "The 'boolean' attribute syntax
> is similar
>  to an enum with only two values:  'true' and 'false'. "
> And in section 4.1.4 the words says "The 'enum' attribute syntax is an
> enumerated
>  integer value that is in the range from 1 to 2**31 - 1 (MAX)."
> Does this mean, that a boolean attribute got a 32 bit size value?
> In the protocol document, it says that a boolean is a byte size!

I think PRO would take precedence here.

> 
> 2. In section 3.2.6.1 'Get-Jobs Request' I wondered, if the attribute
> 'my-jobs' is
> present and set to TRUE, MUST the 'requesting-user-name' attribute be there
> to,
> and if it's not present what should the IPP printer do?

If the client does not supply a value for "requesting-user-name", the
printer MUST assume that the client is supplying some anonymous name,
such as "anonymous".

> 
> Regards
> Henrik Holst
> 
> ___________________________________________________________
>  Henrik Holst
>  Software engineer - developing embedded Printservers
>  i-data International
>  Vadstrupvej 35-43, 2880 Bagsvaerd, Denmark
>  Voice:  (+45) 44366271
>  Fax:    (+45) 44366111
>  Email:  henrik.holst at i-data.com
>  WEB:    www.i-data.com
> 
> 
> 
> 
> 
> 
> 



-----
See the original message at http://www.egroups.com/list/ipp/?start=4487
--
Free e-mail group hosting at http://www.eGroups.com/