<!-- Converted from text/rtf format -->
<P><FONT SIZE=2 FACE="Arial">Another one for the list of anomalies in Printer MIB implementations. Sometimes the prtMarkerSuppliesMarkerIndex is a zero. This is supposed to be the index of the marker with which a particular supply is associated. By law, indices are nonzero. But someone thought that transfer rollers and fusers were consumable supplies that weren't associated with a marker. Surprise! Just try looking up marker zero in the table. </FONT></P>
<P><FONT SIZE=2 FACE="Arial">Easy to code around, but crummy. </FONT>
</P>
<P><FONT SIZE=2 FACE="Arial">rick</FONT>
</P>
<P><FONT SIZE=2 FACE="Arial">----------------------</FONT>
<BR><FONT SIZE=2 FACE="Arial">Richard_Landau(at)dell(dot)com, Stds & System Mgt Architecture, CTO Office</FONT>